Vue de la page 0
MT-600-D12-SL-_
Installation Instructions for Monorail 6
120 Volt Input to 12 Volt Dual
Feed Output
00 Watt Sloped Surface
Mount Magnetic Transformer
1
904-MT-600-D12-SL-04
1718 W. Fullerton Ave
Chicago, IL 60614
Tel: 773-770-1195
Fax: 773-935-5613
www.edgelighting.com
SAVE THESE INSTRUCTIONS!
- Do not install this lighting system in a damp or wet
location.
- Do not conceal or extend bus bar conductor through
building wall.
- To reduce the risk of fire and burns, do not install this
lighting system where the insulated open bus bar
conductors can be shorted or contact any conductive
materials.
- To reduce the risk of the system overheating and possibly
causing a fire, make sure all the connections are tight.
- Do not install fixture assemblies closer than six inches, or
as specified in the fixture installation instructions, to
curtains or similarly combustible materials.
- Turn the electrical power off before modifying the lighting
system in any way.
- The fixtures used with the Edge Lighting systems must be
identified for use with the corresponding Edge Lighting
systems.
- Minimum volume of the electrical box must be 6 cubic
inches (98 cubic centimeters).
- The system is "ETL" listed for USA and Canada only when
all the products used are supplied by Edge Lighting.
- RISK OF FIRE: This product must be installed by a
qualified electrician. Turn the power to the electrical box off
during installation. Read the "Important Safety Instructions"
before installation.
- This product is suitable only for indoor dry locations and
approved for the use at any height above the finished floor.
- This product contains a magnetic transformer with a built-in
dimming coil.
- This product may be dimmed only with a low voltage
magnetic dimmer. Using a dimmer other than specified may
work initially, but will eventually cause transformer failure
and void the warranty. The dimmer must be derated as
indicated by the dimmer manufacturer.
- A typical installation is shown. Specific installation must be
in accordance with the local electrical codes.
- Load each circuit of the surface transformer to MAXIMUM
300 Watt.
GENERAL INFORMATION IMPORTANT SAFETY INSTRUCTIONS
PATENT PENDING
© 2013 Edge Lighting. All Rights Reserved.
Vue de la page 0
1 2 3 4 5

Résumé du contenu

Page 1 - Mount Magnetic Transformer

MT-600-D12-SL-_Installation Instructions for Monorail 6120 Volt Input to 12 Volt Dual Feed Output00 Watt Sloped Surface Mount Magnetic Transformer 190

Page 2

2Install the Surface Mount Transformer4: Connect the provided white and black extension wires to the neutral and hot power wires respectively with

Page 3 - Transformer

310: Connect the white transformer wire to the white extension wire with a wire nut.11: Connect the black transformer wire to the black extensio

Page 4 - 3/8-24 SETSCREW

13 13ONE MONORAIL SECTIONK 8: Place the other Monorail section into the opposite standoff housings. 9: While supporting this Monorail section,

Page 5

POWER FEED ROD2M3 SET SCREW1.5MM ALLEN WRENCH5P1: Remove the wire nuts from the center wires.2: Loosen (DO NOT REMOVE) the bottom M3 set screw on